Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Neuroradiol J ; : 19714009241247462, 2024 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-38622821

RESUMO

INTRODUCTION: Wide-necked bifurcation aneurysms pose significant challenges for endovascular treatment. A recent innovation, the stent plus balloon-assisted coiling technique, combines a stent and a balloon to address these aneurysms effectively. PURPOSE: To evaluate the safety and efficacy of the stent plus balloon-assisted coiling for the treatment of wide-necked bifurcation aneurysms. METHODS: We conducted a retrospective review of our endovascular database to identify patients who were treated with this technique and had a satisfactory angiographic follow-up of at least 24 months. Technical success, initial clinical and angiographic outcomes, procedural complications, and follow-up results were analyzed. Angiographic and clinical outcomes were assessed using Modified Raymond-Roy Classification and Modified Rankin Scale, respectively. RESULTS: Our study included 37 aneurysms in 36 patients (26 females) with a mean age of 56.6 years. Mean aneurysm and neck sizes were 7.3 ± 3.5 mm and 3.7 ± 1.0 mm, respectively. Technical success reached 97.2%, with an immediate occlusion rate of 65.7%. At a mean follow-up of 36.5 ± 9.7 months, final angiographic follow-up showed a 91.9% complete occlusion rate. Three aneurysms did not achieve complete occlusion; however, none required retreatment. Complications developed in 32.4% of the procedures. Mortality and morbidity rates were 5.4% and 2.7%, respectively. A good clinical outcome was observed in 91.9% of patients. CONCLUSION: Our results showed that stent plus balloon-assisted coiling technique allows good angiographic outcomes for wide-necked bifurcation aneurysms. However, overall complication rate is high. Subgroup analysis indicated promising safety and efficacy for MCA bifurcation aneurysms, suggesting this technique could be a valuable option for select aneurysms.

2.
Neurosurg Rev ; 47(1): 123, 2024 Mar 20.
Artigo em Inglês | MEDLINE | ID: mdl-38503965

RESUMO

Low-profile stents may provide significant advantages in Y-stent-assisted coiling due to their miniaturized design and capability to be delivered through a 0.0165-inch microcatheter. We aim to investigate the safety and efficacy of using these newer versions of stents in Y-stent-assisted coiling for the treatment of wide-necked bifurcation aneurysms. We conducted a systematic review of the PubMed, Embase, Cochrane Library, and Web of Science databases up to September 2023, following the PRISMA guidelines. Eligible studies included ≥ 5 patients with intracranial wide-necked bifurcation aneurysms treated with Y-stent-assisted coiling using low-profile stents, providing angiographic and clinical outcomes. Two authors independently handled the search and selection. Primary outcomes were immediate and follow-up aneurysm occlusion, procedure-related complications, aneurysm recanalization, and retreatment. Secondary outcomes included technical success, procedure-related morbidity, procedure-related mortality, procedure-related stroke, and in-stent stenosis at follow-up. We analyzed the data using random-effects meta-analysis. In total, 19 studies including 507 patients with 509 aneurysms were included. 95% of the treated aneurysms were managed using the crossing Y-configuration. Technical success rate was 99%. Immediate adequate aneurysm occlusion was 90%. Follow-up angiographies were available for 443 aneurysms. The mean angiographic follow-up duration was 15.6 ± 1.9 months. The rates for follow-up adequate aneurysm occlusion and complete occlusion were 98% and 89%, respectively. After a mean clinical follow-up of 15 ± 2.4 months, a good clinical outcome was observed in 98% of patients. Overall, procedure-related morbidity and mortality rates were 1.3%, and 0.4%, respectively. Low-profile stents in Y-stent-assisted coiling outperform previous stent versions in terms of safety, efficacy, and technical success rates.


Assuntos
Embolização Terapêutica , Aneurisma Intracraniano , Humanos , Resultado do Tratamento , Estudos Retrospectivos , Stents , Aneurisma Intracraniano/complicações , Angiografia Cerebral
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...